SLIO > Function modules

050-1BA10 - Function modules | Counter modules

Order no.

050-1BA10

TypeFM 050
Module ID08C2 3801

General information

Note-
Features1 Counter 32 Bit (AB)
DC 5 V (difference signal)

Current consumption/power loss

Current consumption from backplane bus75 mA
Power loss0.85 W

Technical data digital inputs

Number of inputs-
Cable length, shielded100 m
Cable length, unshielded-
Rated load voltageDC 20.4...28.8 V
Reverse polarity protection of rated load voltage-
Current consumption from load voltage L+ (without load)20 mA
Rated value-
Input voltage for signal "0"Differential signal RS422
Input voltage for signal "1"Differential signal RS422
Input voltage hysteresis-
Frequency range-
Input resistance120 Ω
Input current for signal "1"-
Connection of Two-Wire-BEROs possible-
Max. permissible BERO quiescent current-
Input delay of "0" to "1"0.8 µs
Input delay of "1" to "0"0.8 µs
Number of simultaneously utilizable inputs horizontal configuration-
Number of simultaneously utilizable inputs vertical configuration-
Input characteristic curve-
Initial data size8 Byte

Technical data digital outputs

Number of outputs-
Cable length, shielded-
Cable length, unshielded-
Rated load voltage-
Current consumption from load voltage L+ (without load)-
Output delay of "0" to "1"-
Output delay of "1" to "0"-
Minimum load current-
Lamp load-
Parallel switching of outputs for redundant control of a load-
Parallel switching of outputs for increased power-
Actuation of digital input-
Switching frequency with resistive load-
Switching frequency with inductive load-
Switching frequency on lamp load-
Internal limitation of inductive shut-off voltage-
Short-circuit protection of output-
Trigger level-
Number of operating cycle of relay outputs-
Switching capacity of contacts-
Output data size10 Byte

Technical data counters

Number of counters1
Counter width32 Bit
Maximum input frequency500 kHz
Maximum count frequency2 MHz
Mode incremental encoder
Mode pulse / direction
Mode pulse-
Mode frequency counter-
Mode period measurement-
Gate input available-
Latch input available-
Reset input available
Counter output available-

Status information, alarms, diagnostics

Status displayyes
Interruptsyes, parameterizable
Process alarmyes, parameterizable
Diagnostic interruptyes, parameterizable
Diagnostic functionsyes, parameterizable
Diagnostics information read-outpossible
Module stategreen LED
Module error displayred LED
Channel error displaynone

Isolation

Between channels-
Between channels of groups to-
Between channels and backplane bus
Between channels and power supply-
Max. potential difference between circuits-
Max. potential difference between inputs (Ucm)-
Max. potential difference between Mana and Mintern (Uiso)-
Max. potential difference between inputs and Mana (Ucm)-
Max. potential difference between inputs and Mintern (Uiso)-
Max. potential difference between Mintern and outputs-
Insulation tested withDC 500 V

Datasizes

Input bytes8
Output bytes10
Parameter bytes23
Diagnostic bytes20

Housing

MaterialPPE / PPE GF10
MountingProfile rail 35 mm

Mechanical data

Dimensions (WxHxD)12.9 mm x 109 mm x 76.5 mm
Weight60 g

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certificationyes

Downloads

[Datasheet]
[Manual]

[STP]