SLIO > Signal modules analog

031-1BB10 - Signal modules analog | Analog input modules

Order no.

031-1BB10

TypeSM 031
Module ID0411 1543

General information

Note-
Features2 inputs 12Bit
Current 0(4)...20mA
2 wire

Current consumption/power loss

Current consumption from backplane bus50 mA
Power loss0.7 W

Technical data analog inputs

Number of inputs2
Cable length, shielded200 m
Rated load voltageDC 24 V
Current consumption from load voltage L+ (without load)20 mA
Voltage inputs-
Min. input resistance (voltage range)-
Input voltage ranges-
Operational limit of voltage ranges-
Operational limit of voltage ranges with SFU-
Basic error limit voltage ranges-
Basic error limit voltage ranges with SFU-
Destruction limit voltage-
Current inputs
Max. input resistance (current range)60 Ω
Input current ranges+4 mA ... +20 mA
0 mA ... +20 mA
Operational limit of current ranges+/-0.5%
Operational limit of current ranges with SFU-
Basic error limit current ranges+/-0.3%
Radical error limit current ranges with SFU-
Destruction limit current inputs (voltage)max. 24V
Destruction limit current inputs (electrical current)max. 40mA
Resistance inputs-
Resistance ranges-
Operational limit of resistor ranges-
Operational limit of resistor ranges with SFU-
Basic error limit-
Basic error limit with SFU-
Destruction limit resistance inputs-
Resistance thermometer inputs-
Resistance thermometer ranges-
Operational limit of resistance thermometer ranges-
Operational limit of resistance thermometer ranges with SFU-
Basic error limit thermoresistor ranges-
Basic error limit thermoresistor ranges with SFU-
Destruction limit resistance thermometer inputs-
Thermocouple inputs-
Thermocouple ranges-
Operational limit of thermocouple ranges-
Operational limit of thermocouple ranges with SFU-
Basic error limit thermoelement ranges-
Basic error limit thermoelement ranges with SFU-
Destruction limit thermocouple inputs-
Programmable temperature compensation-
External temperature compensation-
Internal temperature compensation-
Temperature error internal compensation-
Technical unit of temperature measurement-
Resolution in bit12
Measurement principlesuccessive approximation
Basic conversion time1.15 ms all channels
Noise suppression for frequency>80dB (UCM<20V)

Status information, alarms, diagnostics

Status displayyes
Interruptsyes, parameterizable
Process alarmyes, parameterizable
Diagnostic interruptyes, parameterizable
Diagnostic functionsyes
Diagnostics information read-outpossible
Module stategreen LED
Module error displayred LED
Channel error displayred LED per channel

Isolation

Between channels
Between channels of groups to1
Between channels and backplane bus
Between channels and power supply
Max. potential difference between circuitsDC 75 V/ AC 50 V
Max. potential difference between inputs (Ucm)DC 75 V/ AC 50 V
Max. potential difference between Mana and Mintern (Uiso)-
Max. potential difference between inputs and Mana (Ucm)DC 75 V/ AC 50 V
Max. potential difference between inputs and Mintern (Uiso)DC 75 V/ AC 50 V
Max. potential difference between Mintern and outputs-
Insulation tested withDC 500 V

Datasizes

Input bytes4
Output bytes0
Parameter bytes20
Diagnostic bytes20

Housing

MaterialPPE / PPE GF10
MountingProfile rail 35 mm

Mechanical data

Dimensions (WxHxD)12.9 mm x 109 mm x 76.5 mm
Weight60 g

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certificationyes

Downloads

[Datasheet]
[Manual]