317-2AJ13 - CPUs | CPUs STEP7 programmable, standard

Order no.

317-2AJ13

TypeCPU 317SE/DPM

General information

Note-
FeaturesSPEED7 technology, SPEED-Bus
2 MB work memory
Memory extension (max. 8 MB)
PROFIBUS-DP master / PtP (switchable)
Also configurable via TIA-Portal
SPEED-Bus

Technical data power supply

Power supply (rated value)DC 24 V
Power supply (permitted range)DC 20.4...28.8 V
Reverse polarity protection
Current consumption (no-load operation)200 mA
Current consumption (rated value)1.5 A
Inrush current5 A
I²t0.5 A²s
Max. current drain at backplane bus4 A
Max. current drain load supply-
Power loss6.5 W

Load and working memory

Load memory, integrated8 MB
Load memory, maximum8 MB
Work memory, integrated2 MB
Work memory, maximal8 MB
Memory divided in 50% program / 50% data
Memory card slotMMC-Card with max. 1 GB

Hardware configuration

Racks, max.4
Modules per rack, max.8 in multiple-, 32 in a single-rack configuration
Number of integrated DP master1
Number of DP master via CP4
Operable function modules8
Operable communication modules PtP16
Operable communication modules LAN8

Command processing times

Bit instructions, min.0.01 µs
Word instruction, min.0.01 µs
Double integer arithmetic, min.0.01 µs
Floating-point arithmetic, min.0.06 µs

Timers/Counters and their retentive characteristics

Number of S7 counters2048
S7 counter remanenceadjustable 0 up to 2048
S7 counter remanence adjustableC0 .. C7
Number of S7 times2048
S7 times remanenceadjustable 0 up to 2048
S7 times remanence adjustablenot retentive

Data range and retentive characteristic

Number of flags16384 Byte
Bit memories retentive characteristic adjustableadjustable 0 up to 16.384
Bit memories retentive characteristic presetMB0 .. MB15
Number of data blocks8190
Max. data blocks size64 KB
Number range DBs1 ... 8190
Max. local data size per execution level1024 Byte
Max. local data size per block1024 Byte

Blocks

Number of OBs23
Maximum OB size64 KB
Total number DBs, FBs, FCs-
Number of FBs8191
Maximum FB size64 KB
Number range FBs0 ... 8190
Number of FCs8191
Maximum FC size64 KB
Number range FCs0 ... 8190
Maximum nesting depth per priority class16
Maximum nesting depth additional within an error OB4

Time

Real-time clock buffered
Clock buffered period (min.)6 w
Type of bufferingVanadium Rechargeable Lithium Battery
Load time for 50% buffering period20 h
Load time for 100% buffering period48 h
Accuracy (max. deviation per day)10 s
Number of operating hours counter8
Clock synchronization
Synchronization via MPIMaster/Slave
Synchronization via Ethernet (NTP)no

Address areas (I/O)

Input I/O address area8192 Byte
Output I/O address area8192 Byte
Process image adjustable
Input process image preset256 Byte
Output process image preset256 Byte
Input process image maximal8192 Byte
Output process image maximal8192 Byte
Digital inputs65536
Digital outputs65536
Digital inputs central1024
Digital outputs central1024
Integrated digital inputs-
Integrated digital outputs-
Analog inputs4096
Analog outputs4096
Analog inputs, central256
Analog outputs, central256
Integrated analog inputs-
Integrated analog outputs-

Communication functions

PG/OP channel
Global data communication
Number of GD circuits, max.8
Size of GD packets, max.54 Byte
S7 basic communication
S7 basic communication, user data per job76 Byte
S7 communication
S7 communication as server
S7 communication as client-
S7 communication, user data per job160 Byte
Number of connections, max.32

Functionality Sub-D interfaces

TypeX2
Type of interfaceRS485
ConnectorSub-D, 9-pin, female
Electrically isolated
MPI
MP²I (MPI/RS232)-
DP master-
DP slave-
Point-to-point interface-
5V DC Power supplymax. 90mA, isolated
24V DC Power supplymax. 100mA, non-isolated

TypeX3
Type of interfaceRS485
ConnectorSub-D, 9-pin, female
Electrically isolated
MPI-
MP²I (MPI/RS232)-
DP masteryes
DP slaveyes
Point-to-point interface
5V DC Power supplymax. 90mA, isolated
24V DC Power supplymax. 100mA, non-isolated

Functionality MPI

Number of connections, max.32
PG/OP channel
Routing
Global data communication
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client-
Transmission speed, min.19.2 kbit/s
Transmission speed, max.12 Mbit/s

Functionality PROFIBUS master

PG/OP channel
Routing
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client-
Activation/deactivation of DP slaves
Direct data exchange (slave-to-slave communication)-
DPV1
Transmission speed, min.9.6 kbit/s
Transmission speed, max.12 Mbit/s
Number of DP slaves, max.124
Address range inputs, max.8 KB
Address range outputs, max.8 KB
User data inputs per slave, max.244 Byte
User data outputs per slave, max.244 Byte

Functionality PROFIBUS slave

PG/OP channel
Routing
S7 communication
S7 communication as server
S7 communication as client-
Direct data exchange (slave-to-slave communication)-
DPV1
Transmission speed, min.9.6 kbit/s
Transmission speed, max.12 Mbit/s
Automatic detection of transmission speed-
Transfer memory inputs, max.244 Byte
Transfer memory outputs, max.244 Byte
Address areas, max.32
User data per address area, max.32 Byte

Point-to-point communication

PtP communication
Interface isolated
RS232 interface-
RS422 interface-
RS485 interface
ConnectorSub-D, 9-pin, female
Transmission speed, min.150 bit/s
Transmission speed, max.115.5 kbit/s
Cable length, max.500 m

Point-to-point protocol

ASCII protocol
STX/ETX protocol
3964(R) protocol
RK512 protocol-
USS master protocol
Modbus master protocol
Modbus slave protocol-
Special protocols-

Functionality RJ45 interfaces

TypeX5
Type of interfaceEthernet 10/100 MBit
ConnectorRJ45
Electrically isolated
PG/OP channel
Number of connections, max.4
Productive connections-

Housing

MaterialPPE
MountingRail System 300

Mechanical data

Dimensions (WxHxD)80 mm x 125 mm x 120 mm
Weight420 g

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certificationyes

Downloads

[Datasheet]
[Manual]