300S > Signal modules analog
331-1KF01 - Signal modules analog | Analog input modules
Order no. |
331-1KF01 |
Type | SM 331 |
General information |
|
Note | - |
Features | 8 inputs 13 bit Voltage, current Resistance Resistance thermometer |
SPEED-Bus | - |
Current consumption/power loss |
|
Current consumption from backplane bus | 255 mA |
Power loss | 1.3 W |
Technical data analog inputs |
|
Number of inputs | 8 |
Cable length, shielded | 50 m |
Rated load voltage | - |
Current consumption from load voltage L+ (without load) | - |
Voltage inputs | |
Min. input resistance (voltage range) | 100 kΩ |
Input voltage ranges | -50 mV ... +50 mV -500 mV ... +500 mV -1 V ... +1 V -5 V ... +5 V 0 V ... +10 V -10 V ... +10 V +1 V ... +5 V |
Operational limit of voltage ranges | +/-0.5% ... +/-0.6% |
Operational limit of voltage ranges with SFU | - |
Basic error limit voltage ranges | +/-0.3% ... +/-0.4% |
Basic error limit voltage ranges with SFU | - |
Destruction limit voltage | max. 30V |
Current inputs | |
Max. input resistance (current range) | 100 Ω |
Input current ranges | -20 mA ... +20 mA 0 mA ... +20 mA +4 mA ... +20 mA |
Operational limit of current ranges | +/-0.5% |
Operational limit of current ranges with SFU | - |
Grundfehlergrenze Strombereiche | +/-0.3% |
Radical error limit current ranges with SFU | - |
Destruction limit current inputs (electrical current) | max. 40mA |
Destruction limit current inputs (voltage) | max. 15V |
Resistance inputs | |
Resistance ranges | 0 ... 600 Ohm 0 ... 6000 Ohm |
Operational limit of resistor ranges | +/-0.5% |
Operational limit of resistor ranges with SFU | - |
Basic error limit | +/-0.3% |
Basic error limit with SFU | - |
Destruction limit resistance inputs | max. 15V |
Resistance thermometer inputs | |
Resistance thermometer ranges | Pt100 Ni100 Ni1000 |
Operational limit of resistance thermometer ranges | +/-1K ... +/-1.2K |
Operational limit of resistance thermometer ranges with SFU | - |
Basic error limit thermoresistor ranges | +/-0.8K |
Basic error limit thermoresistor ranges with SFU | - |
Destruction limit resistance thermometer inputs | max. 15V |
Thermocouple inputs | - |
Thermocouple ranges | - |
Operational limit of thermocouple ranges | - |
Operational limit of thermocouple ranges with SFU | - |
Basic error limit thermoelement ranges | - |
Basic error limit thermoelement ranges with SFU | - |
Destruction limit thermocouple inputs | - |
Programmable temperature compensation | - |
External temperature compensation | - |
Internal temperature compensation | - |
Temperature error internal compensation | - |
Technical unit of temperature measurement | °C, °F, K |
Resolution in bit | 13 |
Measurement principle | Sigma-Delta |
Basic conversion time | 61 ms/51 ms / channel |
Noise suppression for frequency | 50 Hz/60 Hz |
Initial data size | 16 Byte |
Status information, alarms, diagnostics |
|
Status display | none |
Interrupts | no |
Process alarm | no |
Diagnostic interrupt | no |
Diagnostic functions | no |
Diagnostics information read-out | none |
Supply voltage display | none |
Group error display | none |
Channel error display | none |
Isolation |
|
Between channels | - |
Between channels of groups to | - |
Between channels and backplane bus | |
Between channels and power supply | - |
Max. potential difference between circuits | - |
Max. potential difference between inputs (Ucm) | DC 2 V |
Max. potential difference between Mana and Mintern (Uiso) | - |
Max. potential difference between inputs and Mana (Ucm) | - |
Max. potential difference between inputs and Mintern (Uiso) | DC 75 V/ AC 50 V |
Max. potential difference between Mintern and outputs | - |
Insulation tested with | DC 500 V |
Datasizes |
|
Input bytes | 16 |
Output bytes | 0 |
Parameter bytes | 21 |
Diagnostic bytes | 0 |
Housing |
|
Material | PPE |
Mounting | Rail System 300 |
Mechanical data |
|
Dimensions (WxHxD) | 40 mm x 125 mm x 120 mm |
Weight | 260 g |
Environmental conditions |
|
Operating temperature | 0 °C to 60 °C |
Storage temperature | -25 °C to 70 °C |
Certifications |
|
UL certification | yes |
KC certification | yes |