300S > Signal modules analog

331-1KF01 - Signal modules analog | Analog input modules

Order no.

331-1KF01

TypeSM 331

General information

Note-
Features8 inputs 13 bit
Voltage, current
Resistance
Resistance thermometer
SPEED-Bus-

Current consumption/power loss

Current consumption from backplane bus255 mA
Power loss1.3 W

Technical data analog inputs

Number of inputs8
Cable length, shielded50 m
Rated load voltage-
Current consumption from load voltage L+ (without load)-
Voltage inputs
Min. input resistance (voltage range)100 kΩ
Input voltage ranges-50 mV ... +50 mV
-500 mV ... +500 mV
-1 V ... +1 V
-5 V ... +5 V
0 V ... +10 V
-10 V ... +10 V
+1 V ... +5 V
Operational limit of voltage ranges+/-0.5% ... +/-0.6%
Operational limit of voltage ranges with SFU-
Basic error limit voltage ranges+/-0.3% ... +/-0.4%
Basic error limit voltage ranges with SFU-
Destruction limit voltagemax. 30V
Current inputs
Max. input resistance (current range)100 Ω
Input current ranges-20 mA ... +20 mA
0 mA ... +20 mA
+4 mA ... +20 mA
Operational limit of current ranges+/-0.5%
Operational limit of current ranges with SFU-
Grundfehlergrenze Strombereiche+/-0.3%
Radical error limit current ranges with SFU-
Destruction limit current inputs (electrical current)max. 40mA
Destruction limit current inputs (voltage)max. 15V
Resistance inputs
Resistance ranges0 ... 600 Ohm
0 ... 6000 Ohm
Operational limit of resistor ranges+/-0.5%
Operational limit of resistor ranges with SFU-
Basic error limit+/-0.3%
Basic error limit with SFU-
Destruction limit resistance inputsmax. 15V
Resistance thermometer inputs
Resistance thermometer rangesPt100
Ni100
Ni1000
Operational limit of resistance thermometer ranges+/-1K ... +/-1.2K
Operational limit of resistance thermometer ranges with SFU-
Basic error limit thermoresistor ranges+/-0.8K
Basic error limit thermoresistor ranges with SFU-
Destruction limit resistance thermometer inputsmax. 15V
Thermocouple inputs-
Thermocouple ranges-
Operational limit of thermocouple ranges-
Operational limit of thermocouple ranges with SFU-
Basic error limit thermoelement ranges-
Basic error limit thermoelement ranges with SFU-
Destruction limit thermocouple inputs-
Programmable temperature compensation-
External temperature compensation-
Internal temperature compensation-
Temperature error internal compensation-
Technical unit of temperature measurement°C, °F, K
Resolution in bit13
Measurement principleSigma-Delta
Basic conversion time61 ms/51 ms / channel
Noise suppression for frequency50 Hz/60 Hz
Initial data size16 Byte

Status information, alarms, diagnostics

Status displaynone
Interruptsno
Process alarmno
Diagnostic interruptno
Diagnostic functionsno
Diagnostics information read-outnone
Supply voltage displaynone
Group error displaynone
Channel error displaynone

Isolation

Between channels-
Between channels of groups to-
Between channels and backplane bus
Between channels and power supply-
Max. potential difference between circuits-
Max. potential difference between inputs (Ucm)DC 2 V
Max. potential difference between Mana and Mintern (Uiso)-
Max. potential difference between inputs and Mana (Ucm)-
Max. potential difference between inputs and Mintern (Uiso)DC 75 V/ AC 50 V
Max. potential difference between Mintern and outputs-
Insulation tested withDC 500 V

Datasizes

Input bytes16
Output bytes0
Parameter bytes21
Diagnostic bytes0

Housing

MaterialPPE
MountingRail System 300

Mechanical data

Dimensions (WxHxD)40 mm x 125 mm x 120 mm
Weight260 g

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certificationyes