223-2BL10 - Signal modules digital | Digital in/output modules

Order no.

223-2BL10

TypeSM 223

General information

Note-
Features16 inputs/ 16 outputs
DC 24 V
Output current 1 A

Current consumption/power loss

Current consumption from backplane bus120 mA
Power loss6.5 W

Technical data digital inputs

Number of inputs16
Cable length, shielded1000 m
Cable length, unshielded600 m
Rated load voltage-
Current consumption from load voltage L+ (without load)-
Rated valueDC 20.4...28.8 V
Input voltage for signal "0"DC 0...5 V
Input voltage for signal "1"DC 15...28.8 V
Input voltage hysteresis-
Frequency range-
Input resistance-
Input current for signal "1"7 mA
Connection of Two-Wire-BEROs possible
Max. permissible BERO quiescent current1.5 mA
Input delay of "0" to "1"3 ms
Input delay of "1" to "0"3 ms
Number of simultaneously utilizable inputs horizontal configuration8
Number of simultaneously utilizable inputs vertical configuration8
Input characteristic curveIEC 61131-2, type 1
Initial data size2 Byte

Technical data digital outputs

Number of outputs16
Cable length, shielded1000 m
Cable length, unshielded600 m
Rated load voltageDC 20.4...28.8 V
Reverse polarity protection of rated load voltage-
Current consumption from load voltage L+ (without load)10 mA
Output current at signal "1", rated value1 A
Output delay of "0" to "1"150 µs
Output delay of "1" to "0"100 µs
Minimum load current-
Lamp load5 W
Parallel switching of outputs for redundant control of a loadnot possible
Parallel switching of outputs for increased powernot possible
Actuation of digital input
Switching frequency with resistive loadmax. 1000 Hz
Switching frequency with inductive loadmax. 0.5 Hz
Switching frequency on lamp loadmax. 10 Hz
Internal limitation of inductive shut-off voltageL+ (-52 V)
Short-circuit protection of outputyes, electronic
Trigger level1.7 A
Number of operating cycle of relay outputs-
Switching capacity of contacts-
Output data size2 Byte

Status information, alarms, diagnostics

Status displaygreen LED per channel
Interruptsno
Process alarmno
Diagnostic interruptno
Diagnostic functionsno
Diagnostics information read-outnone
Supply voltage displaygreen LED
Group error displayred SF LED
Channel error displaynone

Isolation

Between channels-
Between channels of groups to16
Between channels and backplane bus
Insulation tested withDC 500 V

Datasizes

Input bytes2
Output bytes2
Parameter bytes0
Diagnostic bytes0

Housing

MaterialPPE / PA 6.6
MountingProfile rail 35 mm

Mechanical data

Dimensions (WxHxD)50.8 mm x 76 mm x 88 mm
Weight150 g

Environmental conditions

Operating temperature0 °C to 60 °C
Storage temperature-25 °C to 70 °C

Certifications

UL certificationyes
KC certification-

Downloads

[Datasheet]
[Manual]